Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.622
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1348774, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38655391

RESUMEN

Introduction: Crystalline lens overshooting refers to a situation in which the lens momentarily shifts too much from its typical location immediately after stopping the rotational movement of the eye globe. This movement can be observed using an optical technique called Purkinje imaging. Methods: In this work, an experimental setup was designed to reproduce this effect ex vivo using a fresh porcine eye. The sample was rotated 90° around its centroid using a high-velocity rotation stage, and the Purkinje image sequences were recorded, allowing us to quantify the overshooting effect. The numerical part of the study consisted of developing a computational model of the eye, based on the finite element method, that allowed us to understand the biomechanical behavior of the different tissues in this dynamic scenario. A 2D fluid-structure interaction model of the porcine eye globe, considering both the solid parts and humors, was created to reproduce the experimental outcomes. Results: Outputs of the simulation were analyzed using an optical simulation software package to assess whether the mechanical model behaves optically like the real ex vivo eye. The simulation predicted the experimental results by carefully adjusting the mechanical properties of the zonular fibers and the damping factor. Conclusion: This study effectively demonstrates the importance of characterizing the dynamic mechanical properties of the eye tissues to properly comprehend and predict the overshooting effect.

2.
Heliyon ; 10(8): e26840, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38660239

RESUMEN

This study investigates the optimal placement of locking plate screws for bone fracture stabilization in the humerus, a crucial factor for enhancing healing outcomes and patient comfort. Utilizing Finite Element Method (FEM) modeling, the research aimed to determine the most effective screw configuration for achieving optimal stress distribution in the humerus bone. A computer tomography (CT) scan of the humerus was performed, and the resulting images were used to create a detailed model in SOLIDWORKS 2012. This model was then analyzed using ANSYS Workbench V13 to develop a finite element model of the bone. Four different screw configurations were examined: 4 × 0°, 4 × 10°, 4 × 20°, 2 × 20°; 2 × 0°. These configurations were subjected to bending in the XZ and YZ planes, as well as tension and compression along the Z axis. The research identified the 2 × 20°+2 × 0° configuration as the most beneficial, with average stress values below 30 MPa and peak stress values below 50 MPa in 3-point bending at the first screw. This configuration consistently showed the lowest stress values across all loading scenarios. Specifically, stress levels ranged from 20 MPa to 50 MPa for bending in the XZ plane, 20 MPa-35 MPa for bending in the YZ plane, 20 MPa-30 MPa for extension in the Z-axis, and 18 MPa-25 MPa for compression in the Z-axis. The 4 × 10° and 4 × 20° configurations also produced satisfactory results, with stress levels not exceeding 70 MPa. However, the 4 × 0° configuration presented considerable stress during bending and compression in the Z-axis, with stress values exceeding 100 MPa, potentially leading to mechanical damage. In conclusion, the 2 × 20°; 2 × 0° screw configuration was identified as the most effective in minimizing stress on the treated bone. Future work will involve a more detailed analysis of this methodology and its potential integration into clinical practice, with a focus on enhancing patient outcomes in bone fracture treatment.

3.
Heliyon ; 10(8): e29525, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38644850

RESUMEN

In this work, a workflow has been developed for the generation of surrogate metamodels to predict and evaluate failure with a confidence above 95 % in initial service conditions of high-performance cylindrical vessels manufactured in composites by Roll Wrapping technology. Currently, there is no specific testing standardization for this type of vessel and to fill this gap probabilistic numerical models were developed, performed by the Finite Element Method, fed with the material characteristics obtained experimentally by 2D digital image correlation from flat specimens. From the initial numerical model, a surrogate metamodel was generated by stochastic approximations. Once the metamodels were obtained by robust engineering, an experimental ring-ring tensile test was developed under service conditions and deformations were measured by high-precision 3D digital image correlation. Parametric and robust tests showed that the results of the metamodel did not show statistically significant differences, with errors in the rupture part of less than 2 % with respect to the results obtained in the test, being proposed as a basis for new test procedures.

4.
Biomed Eng Lett ; 14(3): 439-450, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38645594

RESUMEN

Purpose: Transscleral ocular iontophoresis has been proposed to deliver charged particulate drugs to ocular tissues effectively by transmitting a weak electrical current through the sclera. The electric fields formed are influenced by the electrode conditions, thus affecting the amount of particulate drugs delivered to the ocular tissues via iontophoresis. Computational simulation is widely used to simulate drug concentrations in the eye; therefore, reflecting the characteristics of the drugs in living tissues to the simulations is important for a more precise estimation of drug concentration. In this study, we investigated the effect of electrode conditions (location and size) on the efficacy of transscleral iontophoresis. Methods: We first determined the simulation parameters based on the comparison of the amount of drug in the sclera in the simulation and in vivo experimental results. The injection of the negatively charged nanoparticles into the cul-de-sac of the lower eyelid was simulated. The active electrode (cathode) was attached to the skin immediately above the injection site, while the return electrode (anode) was placed over the eyebrow. The drug concentration distribution in the eye, based on either the location or size of each electrode, was evaluated using the finite element method with the estimated simulation parameters. Results: Our results indicate that drug permeability varies depending on the location and the size of the electrodes. Conclusion: Our findings demonstrate that the determination of optimal electrode conditions is necessary to enhance the effectiveness of transscleral iontophoresis. Supplementary Information: The online version contains supplementary material available at 10.1007/s13534-024-00359-2.

5.
Int J Numer Method Biomed Eng ; : e3828, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38646858

RESUMEN

As living standards rise, more and more people are paying attention to their own health, especially issues such as cerebral thrombosis, cerebral infarction, and other cerebral blood flow problems. An accurate simulation of blood flow within cerebral vessels has emerged as a crucial area of research. In this study, we focus on microcirculatory blood flow in ischemic brain tissue and employ a 0D-1D geometric multi-scale coupled model to characterize this process. Given the intricate nature of human cerebral vessels, we apply a numerical method combining the finite element method and the third-order Runge-Kutta method to resolve the coupled model. To enhance computational efficiency, we introduce a fast method based on the reduced-order extrapolation algorithm. Our numerical example underscores the stability of the method and convergence accuracy to O h 3 + τ 3 $$ O\left({h}^3+{\tau}^3\right) $$ , while significantly improving the accuracy and efficiency of blood flow simulation, making the mechanism analysis more accurate. Additionally, we present examples detailing variations and distribution of intracranial pressure and blood flow in ischemic brain tissue throughout a cardiac cycle. Both reduced vascular compliance and vascular stenosis can have adverse effects on intracranial cerebral pressure and blood flow, leading to insufficient local oxygen supply and negative effects on brain function. Meanwhile, there will also be corresponding changes in volume flow and pulsatile blood pressure.

6.
Front Bioeng Biotechnol ; 12: 1335788, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38558792

RESUMEN

The function of a specific tissue and its biomechanics are interdependent, with pathologies or ageing often being intertwined with structural decline. The biomechanics of Caenorhabditis elegans, a model organism widely used in pharmacological and ageing research, has been established as biomarker for healthy ageing. However, the properties of the constituent tissues, and their contribution to the overall mechanical characteristics of the organism, remain relatively unknown. In this study we investigated the biomechanics of healthy C. elegans cuticle, muscle tissue, and pseudocoelom using a combination of indentation experiments and in silico modelling. We performed stiffness measurements using an atomic force microscope. To approximate the nematode's cylindrical body we used a novel three-compartment nonlinear finite element model, enabling us to analyse of how changes in the elasticity of individual compartments affect the bulk stiffness. We then fine-tuned the parameters of the model to match the simulation force-indentation output to the experimental data. To test the finite element model, we modified distinct compartments experimentally. Our in silico results, in agreement with previous studies, suggest that hyperosmotic shock reduces stiffness by decreasing the internal pressure. Unexpectedly, treatment with the neuromuscular agent aldicarb, traditionally associated with muscle contraction, reduced stiffness by decreasing the internal pressure. Furthermore, our finite element model can offer insights into how drugs, mutations, or processes such as ageing target individual tissues.

7.
Cureus ; 16(3): e57292, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38559510

RESUMEN

BACKGROUND: Achieving the proper buccolingual inclination of teeth is a cornerstone in orthodontic treatment, directly impacting the attainment of ideal occlusal relationships and long-term stability. A practical torque expression that moves the tooth in its proper position across all three planes is imperative to finish orthodontic cases optimally. The primary focus of this research is to investigate Burstone's hypothesis about Warren torque springs when applied to the rectangular wire. Additionally, it examines the hypothesis of rounding these wires in between the bracket wings of the target tooth to be moved. This study aims to determine whether the rounding of wires, in conjunction with the use of torque springs, influences orthodontic outcomes, addressing a notable gap in current literature and resolving controversies in orthodontic practice. METHODS: A three-dimensional set of maxillary teeth was modeled. A 0.022" MiniSprint™ brackets and Stainless steel archwires of 0.019" × 0.025" and 0.017" × 0.025" (Forestadent, Pforzheim, Germany) were generated. Warren torque spring was modeled and used in the simulation on the upper right central incisor. Four case scenarios were simulated. In two scenarios, the archwires were untouched for both archwire sizes. In comparison, in the other two scenarios, each archwire size was rounded for the upper right maxillary incisor bracket area. Stresses in the Warren torque springs were calculated, the root tip displacement in the four scenarios was measured in millimeters, and both were analyzed. RESULTS: The root tip displacement was highly affected by rounding the archwire. The increase in root tip displacement was 1538% for the Warren torque spring on 0.019" × 0.025" and 783% for 0.017" × 0.025". The amount of root tip displacement was about 18.8 mm for 0.017" × 0.025" with rounding and 12.2 mm for 0.019" × 0.025". The concentration of the stresses in the Warren torque spring was in the neck of the spring next to the coils. CONCLUSION: Rounding the archwires while using the Warren torque spring on a rectangular archwire will increase the efficiency of the spring and, in turn, will exhibit more torque on the tooth. Smaller dimensions of rectangular archwires will give more torque in conjunction with Warren torque springs compared to larger sizes of archwires.

8.
Lasers Surg Med ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38576388

RESUMEN

OBJECTIVES: Knowledge of the physical effects of pulsed dye laser (PDL) treatment of psoriatic lesions is essential in unraveling the remedial mechanisms of this treatment and hence also in maximizing in its disease-modifying potential. Therefore, the main objective of this study was to provide estimates of these physical effects (for laser wavelengths of 585 and 595 nm), with the aim of identifying pathogenic processes that may be affected by these conditions. METHODS: We modeled the laser light propagation and subsequent photothermal heating by numerically solving the transient diffusion and heat equations simultaneously. To this end, we used the finite element method in conjunction with an image-derived psoriatic lesion morphology (which was defined by segmenting blood vessels from a confocal microscopy image of a fluorescently labeled section of a 3 mm punch biopsy of a psoriatic lesion). The resulting predictions of the generated temperature field within the lesion were then used to assess the possibility of stalling or arresting some suspected pathogenic processes. RESULTS: According to our results, it is conceivable that perivascular nerves are thermally denatured, as almost all locations that reach 60°C were found to be within 18 µm (at 585 nm) and 11 µm (at 595 nm) of a blood vessel wall. Furthermore, activation of TRPV1 and TRPV2 channels in perivascular neuronal and immune cells is highly likely, since a critical temperature of 43°C is generated at locations within up to 350 µm of a vessel wall (at both wavelengths) and sustained for up to 700 ms (at 585 nm) and 40 ms (at 595 nm), while a critical temperature of 52°C is reached by locations within 80 µm (at 585 nm) and 30 µm (at 595 nm) of a vessel wall and sustained for up to 100 ms (at 585 nm) and 30 ms (at 595 nm). Finally, we found that the blood vessel coagulation-inducing temperature of 70°C is sustained in the vascular epithelium for up to 19 and 5 ms at 585 and 595 nm, respectively, rendering partial or total loss of vascular functionality a distinct possibility. CONCLUSIONS: The presented approach constitutes a useful tool to provide realistic estimates of the photothermal effects of PDL treatment of psoriatic plaques (as well as other selective photothermolysis-based treatments), yielding information that is essential in guiding future experimental studies toward unraveling the remedial mechanisms of these treatments.

9.
Ann Anat ; : 152267, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38649115

RESUMEN

BACKGROUND: Reasonable postoperative humeroradial and humeroulnar joint spaces maybe an important indicator in biomechanical stability of smart internal fixation surgery for coronoid process basal fractures (CPBF). The aim of this study is to compare elbow articular stresses and elbow-forearm stability under smart internal fixations for the CPBF between normal elbow joint spaces and radius-shortening, and to determine the occult factor of radius-ulna load sharing. METHODS: CT images of 70 volunteers with intact elbow joints were retrospectively collected for accurate three-dimensional reconstruction to measure the longitudinal and transverse joint spaces. Two groups of ten finite element (FE) models were established prospectively between normal joint space and radius-shortening with 2.0mm, including intact elbow joint and forearm, elbow-forearm with CPBF trauma, anterior or posterior double screws-cancellous bone fixation, mini-plate-cancellous bone fixation. Three sets of physiological loads (compression, valgus, varus) were used for FE intelligent calculation, FE model verification, and biomechanical and motion analysis. RESULTS: The stress distribution between coronoid process and radial head, compression displacements and valgus angles of elbow-forearm in the three smart fixation models of the normal joint spaces were close to those of corresponding intact elbow model, but were significantly different from those of preoperative CPBF models and fixed radius-shortening models. The maximum stresses of three smart fixation instrument models of normal joint spaces were significantly smaller than those of the corresponding fixed radius-shortening models. CONCLUSIONS: On the basis of the existing trauma of the elbow-forearm system in clinical practice, which is a dominant factor affecting radius-ulna load sharing, the elbow joint longitudinal space has been found to be the occult factor affecting radius-ulna load sharing. The stability and load sharing of radius and ulna after three kinds of smart fixations of the CPBF is not only related to the anatomical and biomechanical stability principles of smart internal fixations, but also closely related to postoperative elbow joint longitudinal space.

10.
Comput Biol Med ; 175: 108488, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38653066

RESUMEN

BACKGROUND AND OBJECTIVE: Aging is associated with a reduction in muscle performance, but muscle weakness is characterized by a much greater loss of force loss compared to mass loss. The aim of this work is to assess the contribution of the extracellular matrix (ECM) to the lateral transmission of force in humans and the loss of transmitted force due to age-related modifications. METHODS: Finite element models of muscle bundles are developed for young and elderly human subjects, by considering a few fibers connected through an ECM layer. Bundles of young and elderly subjects are assumed to differ in terms of ECM thickness, as observed experimentally. A three-element-based Hill model is adopted to describe the active behavior of muscle fibers, while the ECM is modeled assuming an isotropic hyperelastic neo-Hookean constitutive formulation. Numerical analyses are carried out by mimicking, at the scale of a bundle, two experimental protocols from the literature. RESULTS: When comparing numerical results obtained for bundles of young and elderly subjects, a greater reduction in the total transmitted force is observed in the latter. The loss of transmitted force is 22 % for the elderly subjects, while it is limited to 7.5 % for the young subjects. The result for the elderly subjects is in line with literature studies on animal models, showing a reduction in the range of 20-34 %. This can be explained by an alteration in the mechanism of lateral force transmission due to the lower shear stiffness of the ECM in elderly subjects, related to its higher thickness. CONCLUSIONS: Computational modeling allows to evaluate at the bundle level how the age-related increase of the ECM amount between fibers affects the lateral transmission of force. The results suggest that the observed increase in ECM thickness in aging alone can explain the reduction of the total transmitted force, due to the impaired lateral transmission of force of each fiber.

11.
Acta Biomater ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38570108

RESUMEN

Metallic bioresorbable orthopaedic implants based on magnesium, iron and zinc-based alloys that provide rigid internal fixation without foreign-body complications associated with permanent implants have great potential as next-generation orthopaedic devices. Magnesium (Mg) based alloys exhibit excellent biocompatibility. However, the mechanical performance of such implants for orthopaedic applications is contingent on limiting the rate of corrosion in vivo throughout the bone healing process. Additionally, the surgical procedure for the implantation of internal bone fixation devices may impart plastic deformation to the device, potentially altering the corrosion rate of the device. The primary objective of this study was to develop a computer-based model for predicting the in vivo corrosion behaviour of implants manufactured from a Mg-1Zn-0.25Ca ternary alloy (ZX10). The proposed corrosion model was calibrated with an extensive range of mechanical and in vitro corrosion testing. Finally, the model was validated by comparing the in vivo corrosion performance of the implants during preliminary animal testing with the corrosion performance predicted by the model. The proposed model accurately predicts the in vitro corrosion rate, while overestimating the in vivo corrosion rate of ZX10 implants. Overall, the model provides a "first-line of design" for the development of new bioresorbable Mg-based orthopaedic devices. STATEMENT OF SIGNIFICANCE: Biodegradable metallic orthopaedic implant devices have emerged as a potential alternative to permanent implants, although successful adoption is contingent on achieving an acceptable degradation profile. A reliable computational method for accurately estimating the rate of biodegradation in vivo would greatly accelerate the development of resorbable orthopaedic implants by highlighting the potential risk of premature implant failure at an early stage of the device development. Phenomenological corrosion modelling approach is a promising computational tool for predicting the biodegradation of implants. However, the validity of the models for predicting the in vivo biodegradation of Mg alloys is yet to be determined. Present study investigates the validity of the phenomenological modelling approach for simulating the biodegradation of resorbable metallic orthopaedic implants by using a porcine model that targets craniofacial applications.

12.
Comput Biol Med ; 174: 108402, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38613889

RESUMEN

Porous polymeric scaffolds are used in tissue engineering to maintain or replace damaged biological tissues. Once embedded in body, they are involved into different physical and biological processes, among which their degradation and dissolution of their material can be singled out as one of the most important ones. Degradation parameters depend mostly on the properties of both the material and surrounding native tissues, which can substantially alter the original mechanical parameters of the scaffolds. The aim of this study is to examine the change in the effective mechanical properties of functionally graded additively manufactured polylactide scaffolds with a linear porosity gradient and morphology based on triply periodic minimal surfaces during simultaneous degradation and compressive loading. Two main types of scaffold-degradation processes, bulk and surface erosions are simulated with two suggested modelling methods. The fundamental differences in the proposed approaches are identified and the influence of different types of scaffold morphology on the change in effective elastic properties is evaluated. The results of this study can be useful for design of optimal scaffolds taking into account the effect of the degradation process on their structural integrity.

13.
Heliyon ; 10(7): e28909, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38601654

RESUMEN

The seat significantly contributes to driving safety. Ergonomic seats prevent physical strain and fatigue, so attention and concentration do not drop so quickly, which helps to avoid accidents. The article generally presents the development of seats used in cars and the current areas of use of rotatable seats. Furthermore, it gives an overview of the possible seating positions for fully autonomous vehicles. The article leads the reader through the crash test simulation focusing on the model used. Subsequently, the article presents the research results so far and the possibilities for further development of the driver's seat. The article highlights the change in the driver's movement kinematics as a crucial observation. This change significantly increases the risk of serious injury. In frontal collisions, the modified seat consistently demonstrates results below the specified limit. It is important to note that there are injury values that increase, but these are not a problem because they remain below the limit. In the case of a side collision, the aim was less to reduce injury values and more to better coordinate the kinematics of the passenger's movement during the accident. It can be concluded that this is achievable with the modified seat, as the passenger's movements are notably more predictable and coordinated under these circumstances.

14.
Sensors (Basel) ; 24(7)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38610503

RESUMEN

Ice accumulation on infrastructure poses severe safety risks and economic losses, necessitating effective detection and monitoring solutions. This study introduces a novel approach employing surface acoustic wave (SAW) sensors, known for their small size, wireless operation, energy self-sufficiency, and retrofit capability. Utilizing a SAW dual-mode delay line device on a 64°-rotated Y-cut lithium niobate substrate, we demonstrate a solution for combined ice detection and temperature measurement. In addition to the shear-horizontal polarized leaky SAW, our findings reveal an electrically excitable Rayleigh-type wave in the X+90° direction on the same cut. Experimental results in a temperature chamber confirm capability for reliable differentiation between liquid water and ice loading and simultaneous temperature measurements. This research presents a promising advancement in addressing safety concerns and economic losses associated with ice accretion.

15.
Clin Cosmet Investig Dent ; 16: 75-89, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38632981

RESUMEN

Introduction: Endodontically treated teeth (ETT) undergo extensive structure change and experience high stress during biomechanical function. Stress distribution is influenced by the restoration material and the type of bond between material and tooth structure. The selection of materials that can distribute stress will affect the resistance and retention of ETT to mastication forces, thus biomechanical functions were achieved. Composite has mechanical properties similar to dentin, it can transmit and distribute stresses throughout the tooth surface. The disadvantage of composites in large cavities is their lack of toughness. The addition of fiber to composites can increase their toughness. Purpose: This research is to determine the stress distribution of a fiber-reinforced composite made of polyethylene and e-glass on the mesiolingual cavity of ETT. Materials and Methods: A three-dimensional model of the mandibular molar was prepared for cavity preparation and the formation of restorations using SolidWorks 2021. The models were analyzed with Abaqus 2020 to determine stress concentrations after given vertical and oblique loading. Results: The maximum and minimum principal stress data were obtained to assess material resistance and interfacial damage criterion. Polyethylene fiber shows a more homogeneous stress distribution because the modulus of elasticity is close to the dentin and has a thickness that can reduce the volume of the composite. The E-glass shows the stress concentration on the circumferential fiber and cavity floor. Conclusion: The stress distribution of fiber-reinforced composite on the buccolingual cavity of ETT using the finite element method did not show structural failure in the polyethylene group because the maximum and minimum principal stresses were lower than the strength of the material. Interfacial bond failure occurs at the enamel portion. The maximum and minimum principal values of e-glass indicate structural failure in the circumferential fiber and the base fiber because the stress exceeds the strength of the material. Interfacial bond failure occurred on the circumferential and the cavity floor.

16.
R Soc Open Sci ; 11(4): 231936, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38633347

RESUMEN

Intracranial aneurysm is a pathology related to the deterioration of the arterial wall. This work is an essential part of a large-scale project aimed at providing clinicians with a non-invasive patient-specific decision support tool to facilitate the rupture risk assessment. It will lean on the link between the aneurysm shape clinically observed and a database derived from the in vivo mechanical characterization of aneurysms. To supply this database, a deformation device prototype of the arterial wall was developed. Its use coupled with medical imaging (spectral photon-counting computed tomography providing a spatial resolution down to 250 µm) is used to determine the in vivo mechanical properties of the wall based on the inverse analysis of the quantification of the wall deformation observed experimentally. This study presents the in vivo application of this original procedure to an animal model of aneurysm. The mechanical properties of the aneurysm wall identified were consistent with the literature, and the errors between the numerical and experimental results were less than 10%. Based on these parameters, this study allows the assessment of the aneurysm stress state for a known solicitation and points towards the definition of a rupture criterion.

17.
Int J Paediatr Dent ; 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38584350

RESUMEN

BACKGROUND: One of the primary concerns in the paediatric emergencies is traumatic dental injuries. OBJECTIVE: This study aimed to create trauma in primary teeth and reveal its effects finite element analysis. DESIGN: Three-dimensional models were created using cone-beam computed tomography images, representing a maxillary primary central incisor. An impact force moving at a speed of 10 m/s was simulated on the labial tooth surface in two directions: buccal and incisal. RESULTS: The stress and deformation experienced in the adjacent tooth due to the primary tooth were higher than those generated in the permanent tooth. Forces applied in the incisal direction resulted in higher levels of stress and deformation in the permanent tooth germ. The difference between the stress and deformation values in primary teeth in the forces applied in the buccal and incisal directions is 21% and 75%, respectively; in the permanent tooth germ, this difference was 233% and 100%, respectively. CONCLUSIONS: Based on the findings of this study, it is crucial to thoroughly evaluate not only the affected primary tooth but also the adjacent teeth and the permanent tooth germ in traumatic dental injuries. This comprehensive examination allows for the anticipation and management of potential long-term problems.

18.
Dent Mater ; 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38616152

RESUMEN

OBJECTIVES: This study evaluates the potential for osseointegration and remodeling of customized dental implants made from Titanium-Hydroxyapatite Functionally Graded Material (Ti-HAP FGM) with optimized geometry, using the finite element method (FEM). METHODS: The study utilized CT scan images to model and assemble various geometrical designs of dental implants in a mandibular slice. The mechanical properties of Ti-HAP FGMs were computed by varying volume fractions (VF) of hydroxyapatite (0-20%), and a bone remodeling algorithm was used to evaluate the biomechanical characteristics of the ultimate bone configuration in the peri-implant tissue. RESULTS: The findings of the FEA reveal that osseointegration improves with changes in the density and mechanical properties of the bone surrounding Ti-HAP implants, which are influenced by the varying VF of hydroxyapatite in the FGM. SIGNIFICANCE: Increasing the hydroxyapatite fraction improves osseointegration, and appropriate length and diameter selection of Ti-HAP dental implants contribute to their stability and longevity.

19.
Materials (Basel) ; 17(7)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38612055

RESUMEN

This paper presents an analysis of the effect of the geometry of the end-coil transition zone on the material stress state of a machined compression spring with a rectangular wire cross-section. The literature relationships for determining the stresses in rectangular wire compression springs neglect the effects associated with the geometry of this zone. A series of non-linear numerical analyses were carried out for models of machined compression springs with a wide range of variation in geometrical parameters. The results of these analyses were used to develop a computational model to estimate the minimum value of the rounding radius ρmin, which ensures that the stresses in this zone are reduced to the level of the maximum coil stresses. The model is simple to apply, and allows the radius ρmin to be estimated for springs with a spring index between 2.5 and 10, a helix angle between 1° and 15°, and a proportion of the sides of the wire section between 0.4 and 5.

20.
Materials (Basel) ; 17(7)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38612066

RESUMEN

This paper presents the results of research work on the revised design of a deep hole boring tool. The study was divided into three stages: theoretical, experimental and operational. In the theoretical part, a 3D model of the actual boring bar was created, which was subjected to strength tests using the Finite Element Method (FEM), and then prototypes of new deep hole boring tools were made with structural modifications to the shank part of the tool. For the polymer concrete core of a shank, there was a 14.59% lower displacement, and for the rubber-doped polymer concrete (SBR-styrene butadiene rubber) core of a shank there was a 4.84% lower displacement in comparison to the original boring bar. In the experimental part of the study, the original boring bar and the prototypes were subjected to experimental modal analysis and static analysis tests to compare dynamic and static properties. In the operational part of the study, boring tests were carried out for various workpiece materials, during which the basic parameters of the surface geometric structure (SGS), such as roughness Ra and Rz, were studied. Despite the promising preliminary results of the theoretical and experimental studies, using the described modifications to the boring bar is not recommended.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...